Currents
FE0 MVA
Description:
TPM current measurement.
Front End 0 (PREADU 1) supply current in Amps.
Groups:
currentsReported By: TPM FPGAs
Expected: 0.0 to 2.62
Cleared When Read: No, these are live measurements of continuous (analog) quantities.
Developer info
Tile Method:
get_current(current_name='FE0_mVA')Arguments:
fpga_id (int): Specify which FPGA, 0, 1, or None for both FPGAs
current_name (str): Specify name of current, None for all currents
Returns: TPM currents (dict)
FE1 MVA
Description:
TPM current measurement.
Front End 1 (PREADU 2) supply current in Amps.
Groups:
currentsReported By: TPM FPGAs
Expected: 0.0 to 2.62
Cleared When Read: No, these are live measurements of continuous (analog) quantities.
Developer info
Tile Method:
get_current(current_name='FE1_mVA')Arguments:
fpga_id (int): Specify which FPGA, 0, 1, or None for both FPGAs
current_name (str): Specify name of current, None for all currents
Returns: TPM currents (dict)