FspModeSubarray Class
- class ska_mid_cbf_tdc_mcs.fsp.fsp_mode_subarray_device.FspModeSubarray(cl, name)[source]
Bases:
CbfObsDeviceFspModeSubarray TANGO device class for the FspModeSubarray.
Abstract class for the various FSP Modes Subarray devices to inherit.
- DefaultChannelizerGain
TANGO property
- LRCTimeout
TANGO property
- vccIDs
Assigned VCC IDs
- lastHpsScanConfiguration
The last valid FSP scan configuration sent to HPS.
- channelizerGain
Manual override for fine Channelizer gains; when written, applies the same value for X and Y polarizations.
- is_channelizerGain_allowed
Manual override for fine Channelizer gains; when written, applies the same value for X and Y polarizations.
- class InitCommand(device: Device, logger: Logger | None = None, validator: ArgumentValidator | None = None)[source]
Bases:
InitCommandA class for the FspCorrSubarray’s init_device() “command”.
- do(*args: any, change_event_attrs: list[str] = [], archive_event_attrs: list[str] = [], **kwargs: any) tuple[list[ska_control_model.result_code.ResultCode], list[str]][source]
Stateless hook for device initialisation.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- Return type:
(ResultCode, str)
- class UpdateDelayModelCommand(*args, component_manager: BaseComponentManager, **kwargs)[source]
Bases:
CbfFastCommandA class for the Fsp’s UpdateDelayModel() command.
- is_allowed() bool[source]
Determine if UpdateDelayModel command is allowed.
- Returns:
True if command is allowed, otherwise False
- do(argin: str) tuple[list[ska_control_model.result_code.ResultCode], list[str]][source]
Stateless hook for UpdateDelayModel() command functionality.
- Parameters:
argin – the delay model data
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- Return type:
(ResultCode, str)
- UpdateDelayModel(argin: str) tuple[list[ska_control_model.result_code.ResultCode], list[str]][source]
Update the FSP’s delay model (serialized JSON object)
- Parameters:
argin – the delay model data
- Abort() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Abort the current observing process and move to ABORTED obsState.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- AbortCommands() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Empty out long running commands in queue.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- CheckLongRunningCommandStatus(argin: str) str
Check the status of a long running command by ID.
- Parameters:
argin – the command id
- Returns:
command status
- ConfigureScan(argin: str) tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Configure the observing device parameters for the current scan.
- Parameters:
argin – JSON formatted string with the scan configuration.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- DebugDevice() int
Enable remote debugging of this device.
To modify behaviour for this command, modify the do() method of the command class:
DebugDeviceCommand.- Returns:
the port the debugger is listening on
- DeviceID
TANGO property
- End() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Set obs device from READY to IDLE; currently unimplemented in Mid.CBF, as this is accomplished by GoToIdle.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- EndScan() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
End a running scan.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- ExecutePendingOperations() None
Execute any Tango operations that have been pushed on the queue.
The poll time is initially 5ms, to circumvent the problem of device initialisation, but is reset to 100ms after the first pass.
- GetVersionInfo() list[str]
Return the version information of the device.
To modify behaviour for this command, modify the do() method of the command class.
- Returns:
The result code and the command unique ID
- GoToIdle() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Transit the device from READY to IDLE obsState. To keep in line with LMC, using “GoToIdle” rather than the SKA base class equivalent “End”.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- GroupDefinitions
Device property.
Each string in the list is a JSON serialised dict defining the
group_name,devicesandsubgroupsin the group. A Tango Group object is created for each item in the list, according to the hierarchy defined. This provides easy access to the managed devices in bulk, or individually.The general format of the list is as follows, with optional
devicesandsubgroupskeys:[ {"group_name": "<name>", "devices": ["<dev name>", ...]}, {"group_name": "<name>", "devices": ["<dev name>", "<dev name>", ...], "subgroups" : [{<nested group>}, {<nested group>}, ...]}, ... ]
For example, a hierarchy of racks, servers and switches:
[ {"group_name": "servers", "devices": ["elt/server/1", "elt/server/2", "elt/server/3", "elt/server/4"]}, {"group_name": "switches", "devices": ["elt/switch/A", "elt/switch/B"]}, {"group_name": "pdus", "devices": ["elt/pdu/rackA", "elt/pdu/rackB"]}, {"group_name": "racks", "subgroups": [ {"group_name": "rackA", "devices": ["elt/server/1", "elt/server/2", "elt/switch/A", "elt/pdu/rackA"]}, {"group_name": "rackB", "devices": ["elt/server/3", "elt/server/4", "elt/switch/B", "elt/pdu/rackB"], "subgroups": []} ]} ]
- LoggingLevelDefault
Device property.
Default logging level at device startup. See
LoggingLevel
- LoggingTargetsDefault
Device property.
Default logging targets at device startup. See the project readme for details.
- ObsReset() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Reset the observing device from a FAULT/ABORTED obsState to IDLE.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- Off() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Turn device off.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- On() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Turn device on.
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- Reset() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Reset the device; currently unimplemented in Mid.CBF
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- Scan(argin: int) tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Start an observing scan.
- Parameters:
argin – Scan ID integer
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- SkaLevel
Device property.
Indication of importance of the device in the SKA hierarchy to support drill-down navigation: 1..6, with 1 highest.
- Standby() tuple[list[ska_control_model.result_code.ResultCode], list[str]]
Put the device into standby mode; currently unimplemented in Mid.CBF
- Returns:
A tuple containing a return code and a string message indicating status. The message is for information purpose only.
- TangoClassClass
alias of
FspModeSubarrayClass
- TangoClassName = 'FspModeSubarray'
- adminMode
Read the Admin Mode of the device.
- It may interpret the current device condition and condition of all managed
devices to set this. Most possibly an aggregate attribute.
- Returns:
Admin Mode of the device
- buildState
Read the Build State of the device.
- Returns:
the build state of the device
- commandedState
Read the last commanded operating state of the device.
Initial string is “None”. Only other strings it can change to is “OFF”, “STANDBY” or “ON”, following the start of the Off(), Standby(), On() or Reset() long running commands.
- Returns:
commanded operating state string.
- configurationID
The configuration ID specified into the JSON configuration.
- controlMode
Read the Control Mode of the device.
The control mode of the device are REMOTE, LOCAL Tango Device accepts only from a ‘local’ client and ignores commands and queries received from TM or any other ‘remote’ clients. The Local clients has to release LOCAL control before REMOTE clients can take control again.
- Returns:
Control Mode of the device
- delayModel
Differential off-boresight beam delay model
- deviceID
The observing device ID.
- healthState
Read the Health State of the device.
It interprets the current device condition and condition of all managed devices to set this. Most possibly an aggregate attribute.
- Returns:
Health State of the device
- lastScanConfiguration
The last valid scan configuration.
- loggingLevel
Read the logging level of the device.
Initialises to LoggingLevelDefault on startup. See
LoggingLevel- Returns:
Logging level of the device.
- loggingTargets
Read the additional logging targets of the device.
Note that this excludes the handlers provided by the ska_ser_logging library defaults - initialises to LoggingTargetsDefault on startup.
- Returns:
Logging level of the device.
- longRunningCommandResult
Read the result of the completed long running command.
Reports unique_id, json-encoded result. Clients can subscribe to on_change event and wait for the ID they are interested in.
- Returns:
ID, result.
- lrcFinished
Read info of the finished long running commands.
- Returns:
a list of info JSON blobs of the finished long running commands.
- lrcProtocolVersions
Return supported protocol versions.
- Returns:
A tuple containing the lower and upper bounds of supported long running command protocol versions.
- obsState
Read the Observation State of the device.
- Returns:
the current ObsState enum value
- scanID
The scan identification number to be inserted in the output products.
- simulationMode
Read the Simulation Mode of the device.
- Returns:
Simulation Mode of the device.
- testMode
Read the Test Mode of the device.
Either no test mode or an indication of the test mode.
- Returns:
Test Mode of the device
- versionId
Read the Version Id of the device.
- Returns: