Generating a Solution
MccsStationCalibrator.GenerateCalibrationSolution performs a single
frequency sweep: it configures the station, records a correlation matrix for
each channel in the requested range, solves each one, and stores the results
against a single calibration job. It is a long running command, and the sweep
is complete when it reports COMPLETED.
A calibration job is what ties the results of one sweep together. A single solve of one acquisition, holding the parameters the solve was run with, the antennas masked before it began, and its unique name, with every per-channel solution and the sweep’s phase fit stored against it. It is the unit operations works with, since it is a job, not an individual solution, that is marked preferred and so put into service. See Storing a Solution.
The command takes a JSON argument. Every parameter is optional: the channel
range defaults to 64-448, and the solver parameters default to a gsm sky
model over the whole station. See Solving for a Gain for the solver parameters and
their effect.
See sequence diagram for an overview of the internals:
To run sweeps repeatedly without issuing the command each time, see Scheduling.