HealthRecorder
HealthRecorder derives a device’s healthState and healthReport
from the Tango quality factors of a configured set of attributes. This
page documents how that derivation works.
Attribute quality
Alongside its value, every Tango attribute carries a quality factor
(tango.AttrQuality), which is one of:
ATTR_VALID– the value is within its configured normal range.ATTR_WARNING– the value has crossed a configured warning threshold.ATTR_ALARM– the value has crossed a configured alarm threshold.ATTR_INVALID– the value is not currently valid (for example, not yet read from hardware).
For numeric attributes, the thresholds that drive this quality factor are
configured on the attribute itself, via the min_alarm, max_alarm,
min_warning and max_warning parameters. These are the same
parameters returned by
DeviceProxy.get_attribute_config_ex,
and they can be inspected or changed at runtime using the standard PyTango
attribute configuration API. Tango itself is responsible for comparing each
new value against these thresholds and computing the resulting quality
factor whenever the attribute is updated.
Tracking attribute quality
HealthRecorder is constructed with a device’s trl and a list of
attributes to track. It opens a throwaway MccsDeviceProxy to that
trl and, once the device is exported and the proxy connected,
subscribes to two events per attribute:
a
CHANGE_EVENT, handled byattribute_value_changed, which records the attribute’s latest(quality, value)pair and triggers re-evaluation of health.an
ATTR_CONF_EVENT, handled by_attr_conf_callback– see Attribute configuration changes below.
The most recently observed (quality, value) for each attribute is kept
in an internal cache (_attribute_state), keyed by attribute name. This
cache is the sole input to health evaluation.
Deriving healthState
healthState is derived by taking the worst quality factor across
every tracked attribute, using the severity ordering
ALARM < WARNING < INVALID < VALID (QUALITY_SEVERITY), and mapping
that quality onto a HealthState (QUALITY_TO_HEALTH):
AttrQuality |
HealthState |
|---|---|
ATTR_VALID |
OK |
ATTR_WARNING |
DEGRADED |
ATTR_ALARM |
FAILED |
ATTR_INVALID |
UNKNOWN |
If no attribute has been recorded yet (for example, before any value has
been read from hardware), healthState is HealthState.UNKNOWN.
Deriving healthReport
When every tracked attribute is ATTR_VALID, healthReport is the
fixed string "Health is OK.". Otherwise, the report is built by
selecting every attribute whose quality equals the worst quality
identified above, and rendering one line per attribute in the form:
<attribute name> is in <quality> with value <value>
These lines are joined with newlines, so the report always names every
attribute currently responsible for the reported healthState, along
with the value that triggered it.
Both values are recomputed on every CHANGE_EVENT, and the supplied
health_callback is invoked after every evaluation. Successive equal
values are still reported; deduplication of events is left to Tango’s
native change detection.
Attribute configuration changes
As of PyTango 10.0.2, if an attribute’s alarm/warning thresholds are
reconfigured such that its current value would now be alarming, Tango
does not recompute the attribute’s quality until the next time a value is
pushed for it. The ATTR_CONF_EVENT subscription exists to work around
this: on a configuration change, HealthRecorder calls back into the
owning device via attr_conf_callback, so the device can push a fresh
value for that attribute and have its quality – and therefore
healthState/healthReport – re-evaluated immediately, rather than
waiting for the next natural hardware poll.
Loss of communication
clear_attribute_state() discards every cached (quality, value)
pair and re-evaluates health. This is called by the owning device
when a device loses communication with its hardware,
since none of its previously recorded
attribute values can still be trusted; healthState reverts to
HealthState.UNKNOWN until fresh events arrive.